Fedor Logvin

Saved 5/29/19 8:15 PM from Layfkhaki's councils

Electrical wiring. TOP-10 rules of an electrical wiring.  See details »

 
Video subtitles:
  • 00:00: hello today I want to share with you my experience device wiring in house knowing the basic principles electrical works you can do and perform its save enough money money basis of all the following types construction work after the construction of walls and the roof or before overhaul have the right installation wiring for experts and the right
  • 00:30: wiring this video will not interesting and for all the remaining fans self-taught, I advise inspect it to end try to talk about the most the basic principles wiring nor do I I claim to truth I not try anyone force to do so Anyway, nothing you I do not impose all your hands and you has the right to do at home wiring as you like thrust away ghosts and
  • 01:00: SNIP especially because make her own hands is not difficult but you need to have the knowledge and equipment equipment can buy but I have the necessary knowledge I try to tell popularly [music] [applause] The first is the scheme wiring in most cases
  • 01:30: scheme wiring compiled host building arbitrarily easier speaking from the bulldozer and usually then when over his head he already standing master came do this work circuit drawing It is as follows manner via small pieces or brick walls draw space outlet location and switches near breakers doors and sockets Paul familiar rooms
  • 02:01: you are such a situation it is fundamentally wrong after the end construction work sockets are for furniture and switches for open that door agree not comfortable about the quality performance scheme wiring You can be judged by number electrical extensions and tees used for housing after the end construction and object delivery in granted so the scheme
  • 02:30: electric wiring specifying the place sockets accommodation switches and connection boxes need prepare in advance also need to calculate the necessary load wire cross-section and divided consumers group should be at least two groups ie consumers two circuits one is lighting and other This outlet is better if these two circuit will be each separately room in the house
  • 03:01: in addition, each large appliances oven electrical or boiler must have separate connection with his gun necessarily need agree on this circuit with the location pipe space heating water and gas future arrangement furniture and place stationary household appliances Never put close 50 outlet
  • 03:30: centimeters of various corpse outlet can located at the height of the full that you no most suitable cases it is 30 40 centimeters from the floor but always consider thickness ties and the future flooring if you put in doubt here the exploration or there is no place better let there be an extra outlet than it is not will be required a place placement of furniture in apartment can
  • 04:00: change any moment and now a requirements switches switch should located at the region 90 95 centimeters from the floor and 15 cm from door lift near the door to the room and be sure to side door handle location breakers should be such that there is clearly what breaker for some lighting circuit responsible off
  • 04:31: position breaker must protrude the upper part and in turned lower February 1 keyboards always switches February 1 will be better Keyboard but this requirement does not refers to switches to chandeliers distributive Shield should be It is available dry place preferably near front door a height of not more than meter seventy of sex in any case
  • 05:01: not in the bathroom or fruit so no more in wardrobe next to it should not be be any sanitary connections technical communications The second choice on the right on must have a conductor different color insulation so must take all one wire manufacturer with the same color Gamma lived for Wiring is best use a mono core copper wire
  • 05:30: brand VVG Flat in double insulation beam with additional letters n g which means incombustible necessarily buy wire with labeling rules they have known manufacturing plants ask when buying quality certificate Seller is not it take the wire without marking unknown origin even if it is much less wiring in the house is not on
  • 06:00: one year and here it is impossible not to save use aluminum wires at the same copper wire section withstand power half as much than aluminum and at this content different homes appliances is very important addition to of copper wire more durable lasting less corrode than aluminum and now the attention to capital wiring
  • 06:30: can not use stranded soft PVA grade wire Here's a he double insulated round Yeshe's GDP so they used in mainly for extension of the wire greater resistance a conductivity lower than so single-core it is heated stronger under load although it is soft and lay with manufacturing
  • 07:00: wiring and easier than uses wizard electrician not use for devices wiring in apartment or house both wires different brands and from different materials and now again I ask attention remember one of basic rules on selection section wire to wire not heated one its square or millimeter square
  • 07:30: line size should bear total current does not more than 9 amps that is, so the cable can be connect devices capacity not exceeding two-kilowatt ie one electric starting this should apply Next cable section 1 I lived and combined with relevant circuit breakers to illuminate half square machine 10 ampere
  • 08:00: sockets in the rooms two and a half square 16 amperes electric oven 4 25 square machine 6 ampere electric squares machine 32 amp and another if you plan put the socket ground and you is available equipped for all rules outline then ground to outlets need use three-core copper
  • 08:31: copen modern rules of the organization wiring require installation outlets with only ground but Insert the socket with ground if the wiring two-wire without ground wire it can knock confusing the consumer, and he might think that outlet is protected ground and bitter paid for it third equipment selection with the purchase of outlets and switches pay attention to
  • 09:00: the quality and availability marking and we maintain th power do not buy very cheap and very take expensive the average price in my category According to the difference in price It does not cover the difference As to buy These installation box Enclosures corresponding size and quality all imported outlet and switches intended for installation boxes European standard
  • 09:30: diameter 60 8 if millimeters plan to do a panel of the bar outlets and switches then Enclosures You must be on the sides special projections to join them together on certain distances automatic switches etc. equipment for switchgear Shield buy only well known and proven brands here money saving not worth the 4 mounting
  • 10:02: wiring wires laying in houses with walls of wiring tree do only the outside if necessary make internal then only metal tube sockets and switches and distribution wooden boxes You can leave the house just outside if it is needed put internally then also only special installation boxes for wood designs all places
  • 10:31: wire connections must be Only the outside walls brick house wiring can be both domestic and outdoor near combustible construction of plastic or Tree protection wire used metal cable channel to protect the wire inside the walls used corrugated plastic and prepare a topic outside plastic box for internal wire seals use two
  • 11:00: method, the first on bare brick under plaster on top of the walls and 2 cutting channel kish pipe in the wall, and where placed wiring This procedure has already held at ready walls to avoid damaging the wire in further Refs wire must be fully recessed into the groove Grooves without projections to cut indent use different
  • 11:31: equipment from grinder with a diamond to drive puncher and specifically Wall Chasers it is particularly important that on the existing wire standards must routed only vertically horizontally only straight it is impossible angles how to lay I got around placement vertical sections Don wire should not pass closer than 10-15 centimeters to corners of the room and
  • 12:00: and window and door opening the truth laid not beam they can not binding sites and everyone should be separately distance of at least 3 millimeter between them because the beam wires are less opportunity heat transfer and can cool and must not be crossing of wires between themselves carried by each outlet or switch should go vertically up to the ceiling and then
  • 12:30: in the region of 10 to 25 cm from depending on the ceiling of a thickness ceiling will plaster tension plasterboard placed distribution box and formed horizontal to the floor or ceiling channel pro water with necessity horizontal area can be lay on the ceiling under the floor or horizontal to the floor but
  • 13:02: not less than 25 October centimeters from the level floor such rules there for that after coating wire facings materials you any time know where they are violation of this new can lead to damage to the wiring and tragic effects if you decide hang example painting on the wall or karnizm on the window you You will know that it is necessary or socket
  • 13:30: switch to ceiling as well as at a distance from the ceiling near the ten twenty-five centimeters drill hole and can not be in the all other places It can be done a safe place socket connections box necessarily We need to leave the wire length of at least 25 centimeters choice fastening elements wires to the blue enough today diverse
  • 14:00: single wire strengthen better Now using this fixing herringbone it has different shapes and sizes to drill hole in the wall best not to I solution into bricks to put on the Christmas tree wire and insert into hole conductive fixed mounting metal and plastic sleeves with conductor too exist variety fixing the derivation wires to switchgear shield they must be mark
  • 14:30: paste paint Scotch indicating where exactly is this fifth wire wire connection important note moment wire intended for lighting and sockets cross-section of a half up to two and a half squares can be cut and combine do them branches of law for intended for power electric stoves flow
  • 15:00: ie heaters for power supply appliances section 4 millimeter square and above can not be cut connect and do this branch wire must be unibody go directly from the account to the device In addition to each such a device has to be put some of the month rule is a network no means be overset wires compound
  • 15:30: each case differs Depending on some consumers fit each concrete box but there is one iron rule which is also by no means case can violate attention to the gap in machine or switch should connect wire with phase and not with zero so that when turned off machine or switches on the instrument
  • 16:01: It was not phase wire connection must be reliable and a safe and durable Easy twisting prohibited device regulations electrical how Whatever it was qualitatively done with the true time oxidized contact weakened heated and same result fire twist copper and aluminum, too banned because This guarantee the huge problems in the future as well Now about how
  • 16:30: wire connection the first way is welding wire welding inverter first made and then twisting it end is connected to the cooking but not all homes have a welding apparatus the second way is pressure test special sleeve certain size sold in shop worn joined on wires and using special splash of things pressed into sleeve
  • 17:00: but not everyone again there are ticks and are the most simple about 20 of them three dollars This soldering method twisting wires you can solder at a soldering iron minimum capacity 100 watts adding tin or solder important not to overheat held in conjunction with soldering not to melted isolation of this method more accessible to home with finitely skills after all these methods
  • 17:30: wire connection We need to be insulated shrink or tape all listed species reliable connections but they are not collapsible labor-intensive and have obsolete besides all things for them you need to perform the existence of special equipment and installers of such connection arranges price so expensive I want to say here very important namely remark why not
  • 18:00: necessity use in the home or apartment, such wire connection as welding crimping or soldering because any of the very modern clamping millers manufactured Vaga they Chinese fakes quietly withstand current which is used except residential premises In order for such connections are not It requires any more ment and insulation everyone can connect the wires to the
  • 18:30: via the terminals their own hands and if necessary You can easily change scheme after compound via terminals collapsible again I ask attention is very, very important modern wiring cables up to 2 half squares you need to connect Only with the help of terminal blocks and use them Machines not higher than 16 amperes and cable from four millimeters
  • 19:00: square and above as I hope you remember do not be unite it must lead the whole from switchgear board unit 6 the checks carried out wiring always after conducted wiring needed check again right connections and connecting all wires you can visually check them out and using a device for this test has even special instruments and it is not
  • 19:30: Tester but they are so expensive buy such device Home is not a place Lexi make independent check spend extra hour or two Upon detection of errors and this is necessary to course correct them 7 assembly and installation switchgear the main thing that the shield it should be networks meter and automatic switches one general and somewhat consumer groups all the rest equipment
  • 20:00: ouzo differential or automatic voltage and other it is desirable to put to protect a life households and integrity connected appliances main circuit needed in order to de-energize the apartment one movement and differential Machine needs to do the same act automatically protective device off ouzo It is triggered if network which it
  • 20:31: connected appears differential current leakage so-called when damaged insulation punches on housing heating heating element or other element when you touch people damaged wire or isolated part equipment has instantly disable food network remember that for not protects the network from overload short circuit Here's why
  • 21:00: zavsegda connects consistent with automatic work these two devices so to speak in a pair one protects against leakage current from the other congestion and short circuit if you include sites without the machine and combine the phase and zero Get a short the circuit is no longer work and wiring if there is no other protection devices It burns with uzum differential this machine unique
  • 21:30: device combining in auto switch and the bonds there is differential machine is capable of protect your wiring short circuits and congestion and of leaks current recommended install or ouzo Emergency circuit breakers for each household appliance high power relay voltage, or have m protection devices multifunctional distinguishes
  • 22:00: power when its withdrawal from the set you range of the relay sets for protection appliances included a network of voltage surges this network auto switch should It is accurately calculated load here We need to apply rule that it is better put the machine less power greater than that previously worked Machine and disabled the food overheated wire
  • 22:30: It happened a short circuit and burned wiring remember that the machine It does not protect attached to it appliance and only wire that feeds the appliance from overheating about how a gun to protect cables what section I I mentioned above the main Error here is is that people try to put machines more
  • 23:00: power because of what burns wiring and burn apartment wire is not heated if connected thereto instrument appropriate power so put a vending machine power from above no settlement necessity machines have various categories I I will not explain to you differences you need just remember next to all outlets in the apartment you need to use Machines with English
  • 23:30: the letter d for lighting can be used Machines and category b c for all other power devices can be used Machines category c and again the attention of any It should never be put apartment Machines category d they are intended to powerful tools and motors high starting current 8
  • 24:01: installation Enclosures place for installation box brick or concrete wall can be drill using punch with special nozzle crown diameter 70 75 millimeters in Escutcheon Starts required cable Enclosures established after all needed finishing with walls install Escutcheon Wall with full and ready This process department
  • 24:31: plain holes Escutcheon brick or concrete wall It fills up quickly curable This solution can be dissolved plaster then Enclosures or open the box be inserted into align with the hole and the wall surface horizontally using a level to floor outlet bride and the walls and there was skewed in Well of the parties in plasterboard
  • 25:00: holes Escutcheon cut special cutter diameter 60 8 millimeters and secured by side clamps 9 installation of sockets and switches here There are no special the intricacies you need to remove the top cover or outlet key switch The truth value terminals previously cut them to a length of at more than 10 centimeters tuck the wires on but a scout
  • 25:30: place the appliance Escutcheon until it stops fasten with screws tidy podrozetnik in and tighten until it stops bolts in the niches on the sides are pressed under outlet special Foot mount then install cover sockets or keys switch in place how it's done you You can view link video description under this Video after the installation sockets switches and serve accounts
  • 26:00: the voltage at the wiring and check the working properly all outlets and switches and machines and last make wiring in house can independently their own hands especially a human who knows what is 0, and that such phase but there is many different nuances that wrong It performs even so called specialists in the question such as construction of cottages I'm only fourth
  • 26:30: trying to hit the normal Electrician wiring is a very important section works to trust his unprofessional If you decide to hire electrician pointeresuetes in him how he plans to to work and which he has tool for this present electricians is all set specially a tool for all types Construction of a wiring and If you came to
  • 27:00: electricians who one hammer for two and this must be a neighbor then chase their necks ask where master he has served wiring and ask results from the owners because what he is make an order for Consumables can be understood in its qualifications and conclusions after to the installation watch carefully for his work based recommendations on
  • 27:30: I told you in this video and if you want do yourself wiring too refer to that these rules unclear ask in and comments you all will remember the successful performance wiring depends on accuracy and care and compliance instructions correctly Pick up wire machines and power try to do their own hands qualitative wiring Thank you for your attention and
  • 28:01: I wish you success in creation wiring in your home [music] [applause] [music]